PRAKONSENTRASI DAN ANALISIS ION KADMIUM BERBASIS FLOW INJECTION ANALYSIS

Uswatun Hasanah, - Rusnadi, Bachri Amran

Abstract


CD-imprinted polymers (Cd-IPs) have been synthesized and retensinya properties have been studied for the pre concentration and analysis of cadmium concentration at the level of µ g L-1berbasis technique of flow injection analysis (FIA). This procedure is based on the retention of ions Cd (II) on Cd-IPs are synthesized. Retention cadmium ions can elution quantitatively with a solution of nitric acid directly onto the nebulizer system for atomic absorption spectrometer. The retention capacity of the Cd-IPs acquired for 20.10 mg g-1pada pH optimum and shows a quick retention kinetics. Analytical parameters such as retention capacity, the volume of the sample, the concentration and volume of eluen have been evaluated to obtain a good analytical performance. The system being developed makes it possible to analyze 15 samples per hour, with a limit of detection of the 8 µ g L-1. For the concentration of 50 μg L-1 has obtained precision values expressed as percent relative standard deviation of 1.6 (n = 5). A method of analysis that was developed has been used for the determination of cadmium in river water samples Cidurian, West Java, Indonesia with satisfactory results.

 

Key words:  consentration, analyzing miniscule, cadmium, FIA


References


Almeida, J. A., Barreto, R. E., Novelli, L. B., Castro, F. J., and Moron, S. E.,“Oxidative Stress Biomarkers and Aggressive Behavior in Fish Exposed to Aquatic Cadmium Contamination”. Neotrop.Ichtyol., 2009, Vol 7, pp. 103-108.

Amran, M. B., Panggabean, A. S., Sulaeman, A. and Rusnadi, M,. “Preparation of a Chelating Resin and its Application as a Pre concentration System for Determination of Cadmium in River Water by Flow Injection Analysis”,Spring 2011, Int. J. Environ. Res., 5(2):531-536, ISSN: 1735-6865.

B. Welz, M. Sperling, “Atomic Absorption Spectrometry”, 3rd compl. rev. ed., Wiley-VCH, Weinheim, 1999.

Flora, S. J. S.,“Metal Poisoning: Treatment and Management”. Review Article. Al Ameen, J. Med. Sci, 2009,Vol 2, pp. 4-26.

Liu G., Freund M.S., New Approach for the Controlled Cross-Linking of Polyaniline: Synthesis and Characteization, 1997, Macromol., 30, p.5660.

Panahi, Ahmad., Homayon., Samadi Zadeh., Marjaneh., Tavangari., and Simin. 2012. Nickel Adsorption from Enviromental Samples by Ion Imprinted Aniline-Formaldehyde Polymer. Islamic Azad University and Toosi University of Technology. Tehran : Iran. Vol. 31, No. 3.

Patrick, L., “Toxic Metals and Anti- oxidants. Part II the Role of Anti-oxidant in Arsenic and Cadmium Toxicity – Toxic Metals part II”, 2003, Alternativer Medicine Review.

Pyrzyńska, K. and Szeląg, H.,“On-line Preconcentration system with FAAS detection for determination of cadmium”, Anal.Lett., 2001, 34(12), 2153–2158

Rao, P.T., Daniel, S, Gladis, J.M.,“Tailored Materials for Preconcentration or Separation of Metals by Ion-Imprinted Polymers for Solid-Phase Extraction (IIPSPE)”,Trends in Anal. Chem., 2004, 23 (1): 29- 35.

Sid Kalal, H, Hoveidi, H., Thagiof, M., Pakizevand, N., Almasian, M. R., and Firoozzare, M. A., “Pre-concentration and Determination of Platinum (IV) in Water Samples Using Chelating Resin by Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES)”, Int. J. Environ. Res., 6(3):739-750, Summer 2012, ISSN: 1735-6865.

Z. Fang, “Flow Injection Atomic Absorp tion Spectrometry”, John Wiley & Sons, Chichester, 1995.


Full Text: PDF