ABOUT JOURNAL
PEMANTAU LISTRIK PADA INDUSTRI BERBASIS INTERNET OF THINGS (IOT)
Abstract
Kata kunci : Pemantau listrik, ESP32, IOT, Blynk, Industri.
ABSTRACT
The high electricity consumption in industrial environments drives the need for accurate, efficient, and easily accessible monitoring systems to support energy efficiency and control operational costs. Continuous power monitoring has become an essential part of energy management strategies, especially for high-load equipment such as chiller machines. This research aims to design an Internet of Things (IoT)-based electrical power consumption monitoring system, specifically intended to monitor the three-phase electrical load on a 20 kW chiller machine. The system is developed to provide real-time, flexible information that can be accessed from anywhere. The main component of this system is the Digital Power Meter (DPM), which measures electrical parameters such as voltage, current, and active power. The DPM is connected to the ESP32 microcontroller via the RS-485 communication protocol, which is known for its stability in industrial environments. To measure the current in each phase, Current Transformers (CTs) are used, while an XL-4015 step-down module is utilized to adjust the voltage to a level suitable for the ESP32. The system is programmed using the Arduino IDE, enabling flexible configuration and calibration processes. For the user interface, the Blynk application is used, allowing real-time power consumption monitoring via smartphone, thereby facilitating decision-making related to operational efficiency.Based on direct testing of the device at PT Surya Marga Luhur with a 20 kW chiller load, the measurement results showed that the average active power was recorded at 22.3 kW for phase (RS), 21.4 kW for phase (ST), and 20.0 kW for phase (TR). Meanwhile, the calculated results showed active power of 24.2 kW (RS), 23.2 kW (ST), and 21.7 kW (TR). These data accurately and consistently represent the real power consumed by the system. The difference between the measured and calculated results indicates an error rate of approximately 3%, which is still within the standard tolerance range.
Keywords: Power Monitoring, ESP32, IoT, Blynk, Industry
References
A. SALAM dan MUKHIDIN, Rancang Bangun Sistem Jaringan Multidrop Menggunakan RS485 Pada Aplikasi Pengontrolan Alat Penerangan Kamar Hotel, vol. XI, no. 2, pp. 1-11, 2019.
D. A. Siregar, Alat Pembasmi Hama Tanaman Padi Otomatis Berbasis Mikrokontroler Menggunakan Tegangan Kejut Listrik, vol. I, no. 2, p. 58, 2020.
D. O. D. R. B. Dr. S. Kocer, Programmable Smart Microcontroller Cards, 2021.
DSFDH G. Alvianingsih, Perancangan Sistem Monitoring Pada Pemilah Sampah Otomatis Berbasis Internet Of Things Menggunakan Aplikasi Blynk, vol. XV, no. 1, p. 34, 2023.
E. P. Sitohang, Rancang Bangun Catu Daya DC Menggunakan Mikrokontroler ATmega 8535, vol. VII, no. 2, pp. 135-136, 2018.
F. A. Pratama, REAL TIME DATA LOGGER UNTUK KWH METER DIGITAL TIGA FASA BERBASIS INTERNET OF THINGS (IOT) DAN CLOUD STORAGE, vol. I, no. 1, pp. 67-72, 2021.
F. K. Umam, Perancangan Tempat Sampah Pintar Berbasis Arduino Uno, vol. II, no. 1, p. 230, 2024.
F. Susanto, IMPLEMENTASI INTERNET OF THINGS DALAM KEHIDUPAN SEHARI-HARI, vol. II, no. 1, pp. 35-40, 2022.
Garcés, H. O. et al., Development of an IoT-Enabled Smart Electricity Meter for Real-Time Energy Monitoring and Efficiency, Electronics, 14(6), 1173, 2025.
H. Sugiarto, Kajian Harmonisa Arus Dan Tegangan Listrik di Gedung Administrasi Politeknik Negeri Pontianak, vol. VIII, no. 2, pp. 80-89, 2012.
I. B. G. Purwania, Application of IoT-Based System for Monitoring Energy Consumption, vol. V, no. 2, pp. 81-93, 2020.
ILYAS, ANALISIS KEGAGALAN CURRENT TRANSFORMER (CT) TIPE DUA BELITAN SEKUNDER DENGAN INTI MAGNETIK TERPISAH PADA SISTEM PROTEKSI DAN PEMBATAS DAYA, vol. XXIII, no. 1, 2021.
Imran, M. et al., Design and Development of a Power Quality Based Digital Energy Meter, Engineering Proceedings, 2(1), 13, 2021.
M. Ardiansyah, Sistem Informasi Bencana Banjir (Akusisi Data Multiple Sensor), pp. 1-14, 2011.
R. H. M. Amin, Rancang Bangun Sistem Kendali Dan Monitoring Pengolahan Air Limbah Berbasis PLC, vol. VIII, no. 2, p. 45, 2023.
R. M. Arpin, Rancang Bangun Modul Laboratory Dual Voltage Power Supply, vol. II, no. 1, pp. 48-51, 2021.
SASMITO, Sistem Monitoring Penggunaan Listrik Untuk Audit Energi Pada Bangunan Berbasis IoT, vol. X, no. 5, 2023.
S. D. K, KARAKTERISTIK DIODA (E9), pp. 1-3, 2017.
SITINJAK, Rancang Bangun Konverter AC ke DC Untuk Catu Daya Pada Kontrol Load Break Switch, 2019.
S. KOCER, Programmable Smart Microcontroller Cards, 2021.
S. Sudirham, Analisis Rangkaian Listrik, 2012.
S. Suryaningsih, Rancang Bangun Alat Pemantau Penggunaan Energi Listrik Rumah Tangga Berbasis Internet, vol. V, 2016.
S. Tri Ongko Priyono, MONITORING DAN PENGENDALIAN BEBAN LISTRIK BERBASIS INTERNET OF THINGS (IOT) MENGGUNAKAN ESP32, vol. XI, no. 1, pp. 57-68, 2023.
S. Yusuf Sofyan, Rancang Bangun Konverter Modbus RTU RS485 ke Modbus TCP/IP Berbasis ATMEGA2560, vol. IV, no. 3, pp. 470-477, 2023.
T. K. Wijaya, Perancangan Panel Automatic Transfer Switch dan Automatic Main Failure dengan Kontroler Berbasis Arduino, vol. II, no. 2, p. 210, 2019.
TUKADI, Monitoring Pemakaian Daya Listrik Secara Realtime Berbasis Internet Of Things, 2019.
Tzelepis, D. et al., Voltage and Current Measuring Technologies for HVDC Supergrids, IEEE Access, 8, 203398-203428, 2020.
U. K. Firman Daus, Security Sepeda Motor Berbasis Android, pp. 9-10, 20221.
Varela-Aldás, J. et al., IoT-based Alternating Current Electrical Parameters Monitoring System, Energies, 15(18), 6637, 2022.
Y. Adhimanata, Capacitor Bank Panel Design to Improve Industrial Power System Efficiency and Safety, vol. VII, pp. 227-228, 2024.
YENDI, Analisa Perbaikan Faktor Daya Sistem Kelistrikan, vol. XI, no. 1, pp. 103-113, 2021.
Y. N. I. Fathulrohman, ALAT MONITORING SUHU DAN KELEMBABAN MENGGUNAKAN ARDUINO UNO, vol. II, no. 1, p. 164, 2018.
DOI: 10.33751/teknik.v26i2.13336
Abstract views : 0
Refbacks
- There are currently no refbacks.




